# Percutaneous plating of Weber B fibular fractures.

Saxena A & Yun A.

_J Foot Ankle Surg. pii: S1067-2516(16)30393-3. doi: 10.1053/j.jfas.2016.11.012. \[Epub ahead of print\]_

2017-01-12

## Abstract

The purpose of the present study was to describe a minimally invasive percutaneous technique for plating Weber B distal fibular fractures and to evaluate its efficacy by measuring patient outcomes and hardware removal rates.

The data from 17 patients undergoing percutaneous plating of a distal fibular (Weber B) fracture were prospectively studied. A 4- to 6-hole semitubular plate with 3 screws was used for percutaneously plating. The Roles and Maudsley score was used to assess the patients' activity level.

All fibular fractures had healed clinically and radiographically by 8 weeks after surgery. The postoperative Roles and Maudsley scores had improved significantly. The time required to return to activity was 4.3 ± 2.0 months. Hardware removal was required in 3 patients during the study period, which had an average of almost 4 years postoperatively.

The results of the present study have demonstrated that percutaneous plating is an effective surgical option for treating Weber B distal fibular fractures.

[PubMed abstract](https://www.ncbi.nlm.nih.gov/pubmed/28089595)

## Research topics

-   [Disease Management](https://www.sutterhealth.org/research-search-results?query=%22%5C%22Disease+Management%5C%22%22)
-   [Musculoskeletal Disorders](https://www.sutterhealth.org/research-search-results?query=%22%5C%22Musculoskeletal+Disorders%5C%22%22)

## Related publications

[View all publications](https://www.sutterhealth.org/research-search-results?verticalKey=research_publication)

-   Publication
    
    ### [An Internet-based risk- and stage-tailored osteoporotic fracture risk management program: Effect on knowledge, attitudes and behaviors](https://www.sutterhealth.org/research/publications/osteoporotic-fracture-risk-management-program-1055312543)
    
    Drieling RL, Ma J, Thiyagarajan S, Stafford RS.
    
    J Women's Health (Larchmt). 20(12):1895-907. doi: 10.1089/jwh.2010.2515. Epub 2011 Oct 4.
    
    2011 Dec 01
    
-   Publication
    
    ### [The "not so simple" ankle fracture: avoiding problems and pitfalls to improve patient outcomes.](https://www.sutterhealth.org/research/publications/complex-ankle-fx-pt-outcomes-1055312981)
    
    Hak DJ, Egol KA, Gardner MJ, Haskell A.
    
    Instr Course Lect. 60:73-88.
    
    2011 Jan 01
    
-   Publication
    
    ### [Safe zone for placement of talar screws when fusing the ankle with an anterior plating system.](https://www.sutterhealth.org/research/publications/place-talar-screws-ankle-fused-anterior-plating-1055312984)
    
    Haskell A, Dedini R, Dini M.
    
    Foot Ankle Int. 36(6):730-5. doi: 10.1177/1071100715571440. Epub 2015 Feb 9.
    
    2015 Jun 01
    
-   Publication
    
    ### [Osteoarthritis of the ankle: the role of arthroplasty.](https://www.sutterhealth.org/research/publications/arthroplasty-ankle-osteoarthritis-1055312979)
    
    Chou LB, Coughlin MT, Hansen S Jr, Haskell A, Lundeen G, Saltzman CL, Mann RA.
    
    J Am Acad Orthop Surg. 16(5):249-59.
    
    2008 May 01
    
-   Publication
    
    ### [Synovial chondromatosis of the ankle: report of two cases with 23 and 126 loose bodies.](https://www.sutterhealth.org/research/publications/synovial-chondromatosis-of-the-ankle-1055312460)
    
    Saxena A, St Louis M.
    
    J Foot Ankle Surg. pii: S1067-2516(16)00130-7. doi: 10.1053/j.jfas.2016.02.009. \[Epub ahead of print\]
    
    2016 Apr 05
    

[View all publications](https://www.sutterhealth.org/research-search-results?verticalKey=research_publication)

```json
{"@context":"https://schema.org","@type":"MedicalOrganization","name":"Sutter Health","@id":"https://www.sutterhealth.org/#medicalorganization","url":"https://www.sutterhealth.org","logo":"https://www.sutterhealth.org/static/images/sutter-health-logo.svg","address":{"@type":"PostalAddress","streetAddress":"2200 River Plaza Drive","addressLocality":"Sacramento","addressRegion":"CA","postalCode":"95833","addressCountry":"US"},"areaServed":{"@type":"AdministrativeArea","name":"California"},"sameAs":["https://www.facebook.com/SutterHealth","https://www.instagram.com/sutterhealth/","https://x.com/SutterHealth","https://www.youtube.com/sutterhealth","https://www.linkedin.com/company/sutter-health","https://en.wikipedia.org/wiki/Sutter_Health"]}
```

```json
{"@context":"https://schema.org","@type":"BreadcrumbList","@id":"https://www.sutterhealth.org/research/publications/percutaneous-plate-weber-b-fibula-fx-1055312373#breadcrumblist","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://www.sutterhealth.org/"},{"@type":"ListItem","position":2,"name":"Research","item":"https://www.sutterhealth.org/research"},{"@type":"ListItem","position":3,"name":"Research Publications","item":"https://www.sutterhealth.org/research/publications"},{"@type":"ListItem","position":4,"name":"Percutaneous plating of Weber B fibular fractures."}]}
```

```json
{"@context":"https://schema.org","@type":"MedicalScholarlyArticle","@id":"https://www.sutterhealth.org/research/publications/percutaneous-plate-weber-b-fibula-fx-1055312373#medicalscholarlyarticle","name":"Percutaneous plating of Weber B fibular fractures.","headline":"Percutaneous plating of Weber B fibular fractures.","abstract":"The purpose of the present study was to describe a minimally invasive percutaneous technique for plating Weber B distal fibular fractures and to evaluate its efficacy by measuring patient outcomes and hardware removal rates. The data from 17 patients undergoing percutaneous plating of a distal fibular (Weber B) fracture were prospectively studied. A 4- to 6-hole semitubular plate with 3 screws was used for percutaneously plating. The Roles and Maudsley score was used to assess the patients' activity level. All fibular fractures had healed clinically and radiographically by 8 weeks after surgery. The postoperative Roles and Maudsley scores had improved significantly. The time required to return to activity was 4.3 ± 2.0 months. Hardware removal was required in 3 patients during the study period, which had an average of almost 4 years postoperatively. The results of the present study have demonstrated that percutaneous plating is an effective surgical option for treating Weber B distal fibular fractures.","description":"Results from 17 patients demonstrated that percutaneous plating is an effective surgical option for treating Weber B distal fibular fractures.","keywords":["Disease Management","Musculoskeletal Disorders"],"datePublished":"2017-01-12","url":"https://www.sutterhealth.org/research/publications/percutaneous-plate-weber-b-fibula-fx-1055312373","inLanguage":"en-US","identifier":[{"@type":"PropertyValue","propertyID":"PMID","value":"28089595"},{"@type":"PropertyValue","propertyID":"DOI","value":"10.1053/j.jfas.2016.11.012"}],"sameAs":["https://pubmed.ncbi.nlm.nih.gov/28089595/","https://doi.org/10.1053/j.jfas.2016.11.012"],"isPartOf":{"@type":"Periodical","name":"J Foot Ankle Surg"},"author":[{"@type":"Person","name":"Saxena A"},{"@type":"Person","name":"Yun A"}],"sourceOrganization":{"@type":"MedicalOrganization","name":"Palo Alto Medical Foundation Research Institute"},"about":[{"@type":"DefinedTerm","name":"Disease Management","url":"https://www.sutterhealth.org/research-search-results?facets=%5B%7B%22i%22%3A%22c_researchTopics.name%22%2C%22v%22%3A%5B%22Disease+Management%22%5D%7D%5D&verticalKey=research_publication"},{"@type":"DefinedTerm","name":"Musculoskeletal Disorders","url":"https://www.sutterhealth.org/research-search-results?facets=%5B%7B%22i%22%3A%22c_researchTopics.name%22%2C%22v%22%3A%5B%22Musculoskeletal+Disorders%22%5D%7D%5D&verticalKey=research_publication"}],"mainEntityOfPage":{"@type":"WebPage","@id":"https://www.sutterhealth.org/research/publications/percutaneous-plate-weber-b-fibula-fx-1055312373","breadcrumb":{"@id":"https://www.sutterhealth.org/research/publications/percutaneous-plate-weber-b-fibula-fx-1055312373#breadcrumblist"}}}
```